Rig OutAsk a question
Flower room as installed: rows of HPS fixtures, fabric air ducts and ceiling fans along the room

1 / 6

Conviron room systems

Conviron Flower Room System 1: five rooms, sensors and fans

RVF-108

The equipment from five Conviron controlled-environment flower rooms, sold as one complete system and itemised down to serial numbers: 10 Conviron room control panels, 14 RefPlus hydronic air handlers, 300 DLI Joule 1000 W HPS fixtures, HEPA inlet fans, pump stands, an Argus nutrient injection system, 72 circulation fans, 4 Meter Group Aroya climate station sets and 20 Multifan destratification fans. It is packed in its own 40 ft sea can.

Asking price

CA$265,000

Canadian dollars, plus applicable taxes. Offers are welcome.

Sold as is, where is. Inspection by appointment. Freight quoted per lot, buyer's account. Terms of sale.

Overview

This package is the working equipment from five Conviron flower rooms: the room control panels, the hydronic air handlers that condition each room, the lighting, the filtered fresh-air inlets, the glycol pump stands, the nutrient injection system, a climate and root-zone sensor set for the rooms and a set of destratification fans. It was engineered and installed as one system, and it is sold the same way: one complete system.

Each of the five two-panel sets pairs a 120/208 V panel with a 347/600 V panel. The rooms are lit by Dutch Lighting Innovations Joule 1000 W double-ended HPS fixtures and conditioned by RefPlus CSH-032-8 hydronic air handlers on 600 V three-phase power. Conviron and RefPlus are both Canadian manufacturers.

Four Meter Group Aroya climate station sets cover room air and the root zone. Twenty Multifan fans hang in the room ceilings to keep air moving evenly and break up the warm layer that gathers under the roof.

The photographs show the equipment as it was installed, before our crew removed it. The other Conviron room packages are listed separately; ask us about buying more than one.

What's included

  • Room control panels: 10 Conviron panels in five two-panel sets (one 120/208 V and one 347/600 V panel per room). 1 FLWR2763 set (S/N 180087), 3 FLWR3063 sets (S/N 180088, 180089, 180090) and 1 FLWR2370 set (S/N 180095). Used, packed in closed crates.
  • Air handling: 14 RefPlus CSH-032-8 hydronic air handlers, 600 V. 12 have recorded serial numbers (D2019070728, D2019070729, D2019070730, D2019070731, D2019070865, D2019070870, D2019070892, D2019070917, D2019070922, D2019070934, D2019070935, D2019070936) and 2 are additional units of the same model. Used, each on its own base under a poly shroud.
  • Lighting: 300 Dutch Lighting Innovations DLI Joule-Series 1000 W double-ended HPS grow lights, in three lots of 100. Used, packed in fixture cassettes.
  • Fresh air: 12 Conviron 292231R00 HEPA inlet fan set-ups (6 lots of 2), the filtered fresh-air inlets for the rooms.
  • Hydronics: 6 Conviron hydronic glycol pump stands for the flower rooms (2 in. pipe, 1 in. heat exchanger) and 2 Conviron hydronic pump stands (1-1/4 in. pipe).
  • Nutrient injection: 1 Argus Multi Feed RM100 nutrient injection system, for greenhouse vegetable and flower crops.
  • Air movement: 72 electric circulation fans, a mixed lot of Global Industrial 18 in. and Active Air 16 in. fans, in two lots of 36.
  • Sensing: 4 Meter Group Aroya climate station sets. Each set is a climate station, an Aroya repeater, 5 Aroya sensor noses and 5 TEROS 12 advanced soil moisture, temperature and EC sensors.
  • Destratification: 20 Multifan T4E40K7M81160 fans, 16 in., on pallets.
  • Container: 1 40 ft sea can, which the package is packed in.
Full item register (13 lines)
Items in this package
ItemQtyMakeModel
Global industrial 18 in. and active air 16 in. electric fans36Global Industrial / Active Air
40 ft. seacan container1
Conviron hydronic glycol pump stand (2 in pipe, 1 in heat exchanger)6ConvironHydronic glycol pump stand
Hydronic pump stand (1-1/4 in pipe)2ConvironHydronic pump stand
RefPlus hydronic air handler, flower room type (additional)2RefPlusCSH-032-8
Conviron flower room panels — 2 per room (one 120/208 V, one 347/600 V)2ConvironFLWR2763
Conviron flower room panels — 2 per room (one 120/208 V, one 347/600 V)6ConvironFLWR3063
Conviron flower room panels — 2 per room (one 120/208 V, one 347/600 V)2ConvironFLWR2370
RefPlus hydronic air handler, flower room type12RefPlusCSH-032-8
Argus multi feed RM100 nutrient injection system for green house, vegetables, flower crops etc.1ArgusMULTI FEED RM100
Dutch Lighting Innovations Joule 1000 W DE grow light300Dutch Lighting InnovationsDLI Joule-Series 1000W DE 347V
Climate station set44Meter Group
Pallets of Multifans20MultifanT4E0K7M81160

Specifications

Package1 complete system: five Conviron flower rooms, sold together. Makers: Conviron, RefPlus, Dutch Lighting Innovations, Argus, Global Industrial, Active Air, Meter Group, Multifan.
Panels: FLWR2763 set (1 set, 2 panels)Conviron. S/N 180087. 120/208 V 3 ph 60 Hz, MCA 16.8 A, MOP 20 A, plus 347/600 V 3 ph 60 Hz, MCA 130.5 A, MOP 125 A. Used, closed crate. Ships in the sea can.
Panels: FLWR3063 sets (3 sets, 6 panels)Conviron. S/N 180088, 180089, 180090 (one per set). Each set: 120/208 V 3 ph 60 Hz, MCA 16.8 A, MOP 20 A, plus 347/600 V 3 ph 60 Hz, MCA 120.5 A, MOP 125 A. Used, closed crates. Ships in the sea can.
Panels: FLWR2370 set (1 set, 2 panels)Conviron. S/N 180095. 120/208 V 3 ph 60 Hz, MCA 16.8 A, MOP 20 A, plus 347/600 V 3 ph 60 Hz, MCA 130.5 A, MOP 150 A. Used, closed crate. Ships in the sea can.
Air handlers (14)RefPlus CSH-032-8, hydronic, flower room type. 600 V 3 ph 60 Hz, 5.0 HP, 6.0 A FLA, MCA 7.5 A, max fuse 15 A. Used, poly shroud on own base. Ships with the package.
Air handler serial numbers (12 of 14)D2019070728, D2019070729, D2019070730, D2019070731, D2019070865, D2019070870, D2019070892, D2019070917, D2019070922, D2019070934, D2019070935, D2019070936. The other 2 units have no recorded serial.
Lighting (300)Dutch Lighting Innovations DLI Joule-Series 1000 W DE, HPS. 347 V +/-10%, 50-60 Hz, 1045 W typical, 3.0 A typical. Used, fixture cassettes. Ships in the sea can.
HEPA inlet fans (12)Conviron 292231R00, filtered fresh-air inlet set-ups. No electrical data recorded. Ships in the sea can.
Pump stands (8)Conviron hydronic. 6 glycol stands with 2 in. pipe and 1 in. heat exchanger; 2 stands with 1-1/4 in. pipe. Ships in the sea can.
Nutrient injection (1)Argus Multi Feed RM100. No electrical data recorded. Ships in the sea can.
Circulation fans (72)Global Industrial 18 in. and Active Air 16 in. electric fans, mixed. No electrical data recorded for this lot. Ships with the package.
Aroya climate station sets (4)Meter Group. Per set: climate station, Aroya repeater, 5 sensor noses, 5 TEROS 12 sensors. The record gives one climate station number (H1110005991) and one sensor nose number (H3210017025) for all four sets; individual serials are read at inspection. Ships with the package.
Destratification fans (20)Multifan T4E40K7M81160, 16 in. (40 cm), 3,180 CFM, 315 W per fan (packing-list figures). On pallets. Ships with the package.
Container (1)40 ft sea can, the package's own.

Condition

Used, with about nine months in service. The system was removed from service by our crew in a professional decommission. The Conviron panels are packed in closed crates, the air handlers are shrouded in poly on their own bases, the light fixtures are packed in cassettes and the Multifan fans are stretch-wrapped on pallets.

LED lighting is not part of this package; the room lighting is the 1000 W HPS listed. The benches seen in the room photographs are not included. Nameplate photographs and serial numbers are available on request. We have not tested the equipment since removal. Aroya hardware is built to report to the maker's Aroya platform. Confirm account set-up and activation for used hardware with the maker before purchase.

Sold as is, where is. Inspection is welcome by appointment.

Well suited to

  • Controlled-environment growers building or expanding flower rooms
  • Growers who want climate and root-zone sensing and air destratification included with the rooms
  • Plant-science and agricultural research facilities
  • Vertical farms and indoor produce operations
  • Greenhouse operators adding sealed, lit production rooms
  • Integrators and contractors fitting out a new facility with matched equipment

Load-out and shipping

The package is packed in its own 40 ft sea can. Per our load sheet, the room control panels, HPS lights, HEPA inlet fans, pump stands and Argus unit are loaded in the can. The air handlers, circulation fans, Aroya sets and Multifan fans ship with the package.

Rig Out dismantles, crates and loads, and can prepare export packing. FOB Port of Vancouver or Edmonton rail on request. Freight is quoted per lot and is on the buyer's account. Located in the Edmonton area, Alberta, Canada. Export paperwork is provided for buyers outside Canada.

Email us

Ask a question

We reply within one business day. Prices are in Canadian dollars. Sold as is, where is; see the terms of sale. We use your details only to reply and deal with your enquiry; see our privacy notice.